- All Kinds Of Life Safety Goods
- Fire Safety Plan & Evacuation Plan
- Fire Door And Passive Fire Protection
- Fire Pump & Sprinkler System
- Fire Pump and Hydrant System
- Fire Detection System
- Industrial Automation
- Fire Detection System
- Fire Protection System
- Industrial Power & Electrical Solution
- Fire Safety And Security
- Manufacture Supply & Installation
Wiring of Addressable Fire Alarm System
Description
Gold Supplier 4/8/16 Zones Conventional Fire Alarm Control Panel
Fire alarm control panel |
SR-P01-4 4 zones conventional fire alarm control panel |
SR-P01-8 8 zones conventional fire alarm control panel |
SR-P01-16 16 zones conventional fire alarm control panel |
The SR-P01 Series Conventional Fire Alarm Control Panel is a 24 volt, four to sixteen-zone, Class B, Conventional Fire Alarm Control Panel. Designed exclusively to meet the latest market requirements and future ULC codes, the highly cost-effective SR-P01 Series can be used in a variety of low- to mid-sized applications.
Main Features:
Four, Eight, Sixteen Zone Style B (Class B) Initiating Device Circuits (IDCs), All zones accept
two-wire smoke detectors and any normally-open contact devices.
Two Supervisory Input with DC12V output, ideal to connect security alarm devices.
Three General Alarm, Trouble and Supervisory, Form A Relay Output.
One, Two, Four Built-in Sound Output, Style Y (Class B) Notification Appliance (Signal) Circuits
(NACs), NACs may be programmed: Silenceable or Non-Silenceable.
3.0 amps of total system power. Resettable DC24V & Non-resettable DC24V Output.
Zone Input Short Circuit can be set to “Alarm” or ” Fault” mode.
RS485 Communication Port (optional).
Automatic/Manual mode can be programmed.
Disable/Enable control per Zone (IDC) can be programmed.
Disable/Enable Sound Output(NACs) can be programmed.
Technical specification:
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive)
Reviews (0)
Be the first to review “Wiring of Addressable Fire Alarm System” Cancel reply
Shipping & Delivery
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Fire Doors
Accessories, Fire Detection System, Fire Door And Passive Fire Protection, Industrial Automation, Industrial Power & Electrical Solution
Brand | Golden House (GH) | ||
Standard | UL 10(b),UL 10(c) /NFPA/ASTM /UBC7-2 | ||
Certifications | INTERTEK(WHI),FM,UL | ||
Fire rated time | 45min,90min,up to 180 min | ||
Door Size (single) | standard width up to 4'0"(1200mm ) Height up to 8'0"(2440mm); customized size is available . | ||
Leaf thickness:1 3/4" standard ( 44.5mm ) | |||
Frame jamb depth:100-300mm | |||
Door size (Double) | Maximum size is 8'x8'(2440x2440mm) | ||
Door leaf sheet | 20Ga-18Ga (1.0/1.2mm).customized level is available | ||
Door frame sheet | 16Ga.(1.5mm) ,customized level is available | ||
Opening | swing /inward or outward | ||
Type | 2panel/6panel/flush panel/vision lite /louver | ||
Material of leaf and frame | cold roll steel or Galvanized Steel or Galvannealed Steel | ||
Filling material | Honeycomb,Polystyrene,Mineral Fire Board | ||
Surface finish | factory Primer /finsih paint/power coated/wood grain finished | ||
Color | RAL color system or be customized as well | ||
Application | Suitable for building project,business,home decoration (Office,hotle,church,home and so on ) | ||
Packing | in wooden case or steel pallet package |
Industrial Cable Tray
Accessories, All Kinds Of Life Safety Goods, Fire Detection System, Fire Detection System, Fire Door And Passive Fire Protection, Fire Protection System, Fire Pump & Sprinkler System, Fire Pump and Hydrant System, Fire Safety And Security, Fire Safety Plan & Evacuation Plan, Industrial Automation, Industrial Power & Electrical Solution, Manufacture Supply & Installation
UNIT-1 POWER DISTRIBUTION AND REGULATIONS